Standard: IEC60137, GB/T4109.
Rated voltage?12kV-0.5kV
Rated current?10A-8000A
Temperature:  -50 ? to +55?
Altitude: 1000m?conferring with consumer if above 1000m?
Pollution class?? for indoor, ? for outdoor.

CWW Porcelain wall bushing

CWW Porcelain wall bushing is composed of porcelainbushing, conductor, mounting flange and end accessory. The main insulator is porcelain sheds. The mounting flange is normally grounded. The conductor passes through the heavy current. The current-carrying conductor is busbar.

   

Features

Porcelain wall bushing comprises porcelain bushing, a current-carrying conductor, an intermediate flange, and end accessories. The main insulation is porcelain sleeves. The intermediate flange is normally grounded. The current conductor of the wall bushing is a copper or aluminum busbar. The conductor passes through the HV current. The end accessories serve as a connection between the conductor and the porcelain sheds. The surface of the porcelain sleeves is provided with an umbrella to increase the creepage distance and improve the discharge characteristics. To increase the corona and sliding flashover voltage of 12-40.5kV bushing, the porcelain sleeves are provided with large sleeves on both sides of the flange and covered with semi-conductive glaze.

Parameters

Standard: IEC60137, GB/T4109.
Rated voltage:12kV-0.5kV
Rated current:10A-8000A
Temperature:  -60 ℃ to +55 ℃
Altitude: 1000m?conferring with consumer if above 1000m?
Pollution class: for indoor, ? for outdoor.

Operation
voltage
Um(kV)
Rated voltage
(kV)
Power frequency withstand voltage
(kV)
Lightning impulse withstand voltage (peak) (kV) Rated short-time thermal current
(kA)
dry wet
12 10 28 28 75 25Ir
24 20 50 50 125 25Ir
40.5 35 80 95 200 25Ir

Current value and bending failure load?

Rated current(A) 250 400 630 1250 1600 2000 3150 4000
Bending load≥ kN 4 4 4 4 4 8 8 8

Installation

There are two installation methods for bushings on walls or tank shells: forward installation and reverse installation. The copper conductor wall bushing has both methods, which often easily make mistakes during operation, resulting in a shortened discharge distance and affecting bushing performance. The aluminum conductor and busbar wall bushing have unified reverse installation, which effectively utilizes the height of the porcelain bushing and reduces the size of the bushing.